| Range of Product | Harmony Safety Automation |
|---|---|
| Product or Component Type | Safety module |
| Safety module name | XPSUVN |
| Safety module application | For zero speed detection |
| Function of module | Monitoring 3-phase motor Monitoring 3-phase motor with star-delta starting Monitoring 3-phase motor with variable number of poles Monitoring 3-phase motor with variable number of poles and star-delta starting Monitoring dc motor Monitoring servo motor Monitoring 3-phase motor supplied by variable speed drive Monitoring 3-phase motor supplied by servo drive Controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST |
| Safety level | Can reach PL e/category 3 for normally open relay contact ISO 13849-1 Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 |
| Safety reliability data | MTTFd > 30 years ISO 13849-1 Dcavg = 98.9 % ISO 13849-1 PFHd = 2.44E-9 1/h ISO 13849-1 HFT = 1 IEC 62061 PFHd = 2.44E-9 1/h IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 2.44E-9 1/h IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1 |
| Product Certifications | TÜV cULus |
| [Us] Rated Supply Voltage | 48...240 V AC/DC - 10...10 % |
| Output type | Relay, 1 NO, volt-free |
| Number of additional circuits | 2 solid state outputs |